Search options

Search
Search by author
Between Dates
to
Volume and Number
&

Spemd Logo

Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial

Rev Port Estomatol Med Dent Cir Maxilofac | 2017 | 58 (1) | 32-38




Original research

Damage on tooth enamel after removal of orthodontic adhesive by Arkansas-stone and tungsten carbide burs

Lesão do esmalte após remoção de adesivo ortodontico por pedra de Arkansas e pontas laminadas de carbeto de tungsténio


a School of Dentistry, School of Health Sciences (FCS), Universidade Fernando Pessoa (UFP), Porto, Portugal
b School of Dentistry (FMDUP), University of Porto (UP), Porto, Portugal
c Center for Microelectromechanical Systems (CMEMS), Department of Mechanical Engineering (DEM), University of Minho, Guimarães, Portugal
d Post-graduate Program in Dentistry (PPGO), Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
Mónica Morado Pinho - monicap@ufp.edu.pt

  Show More



Volume - 58
Issue - 1
Original research
Pages - 32-38
Go to Volume


Received on 25/10/2016
Accepted on 18/12/2016
Available Online on 31/05/2017


Original research

 

Damage on tooth enamel after removal of orthodontic adhesive by Arkansas’ stone and tungsten carbide burs

Lesão do esmalte após remoção de adesivo ortodontico por pedra de Arkansas e pontas laminadas de carbeto de tungsténio

 

Mónica Morado Pinhoa,b,*, Gustavo F.V. Pintoa, Pedro Mesquitab, Filipe S. Silvac, Júlio C. M. Souzac,d, Afonso Pinhão Ferreirab, Bruno Henriquesc

a School of Dentistry, School of Health Sciences (FCS), Universidade Fernando Pessoa (UFP), Porto, Portugal b School of Dentistry (FMDUP), University of Porto (UP), Porto, Portugal c Center for Microelectromechanical Systems(CMEMS), Department of Mechanical Engineering (DEM), University of Minho, Guimarães, Portugal d Post-graduate Program in Dentistry (PPGO), Federal University of Santa Catarina (UFSC), Florianópolis, Brazil

 

*Correspondence to:

 

http://doi.org/10.24873/j.rpemd.2017.05.011

 

Abstract

Objectives: The main aim of this study was to compare the effectiveness of two different methods to remove orthodontic composite adhesives from enamel concerning the surface damage and remnant composite adhesive on the surfaces.

Methods: Human molars were stored in buffer solution at room temperature before bonding the brackets. Teeth were ultrasonically cleaned in distilled water before bonding procedure.

Ninety two brackets were randomly bonded to the buccal surface of twenty three molars using a composite-based adhesive system. After 15 days, the orthodontic composite adhesives were removed by using Arkansas’ stone or multi-blade tungsten burs. After debonding process, the remnant composite adhered to the tooth as well as the teeth surfaces were analyzed by photographic images at x40 magnification concerning the (ARI) adhesive remnant or (SRI) surface roughness index. Also, enamel surfaces were inspected by field emission guns scanning electron microscopy (FEGSEM) before bonding and after bracket detachment.

The statistical analysis was performed using SPSSR Statistics vs.18.0, considering a significance level of 0.05 to one-way ANOVA. Tukey’s test was used for multiple comparisons and Chi-square tests were used to analyze the association between categorical variables.

Results: ARI results revealed no statistically significant differences between the two methods of bracket removal (p=0.283). Considering SRI, statistically significant differences were detected between the two procedures (p<0.001) considering all worn surfaces revealed lower surface roughness after removal of adhesive by Arkansas stone than that recorded on worn surfaces after removal using tungsten carbide burs.

Conclusion: The removal of orthodontic adhesive promoted less damage on enamel surfaces by using Arkansas stone at low rotation. Nevertheless, finishing procedures can decrease the roughness on enamel without additional damage.

Keywords: Brackets, Enamel damage, Orthodontic adhesives

 

Resumo

Objetivos: O objetivo deste estudo foi comparar a eficácia de dois métodos diferentes de remoĉntico.

Métodos: Foram utilizados 92 brackets colados em 23 molares previamente selecionados de acordo com os criterios de inclusao/exclusao. Uma vez removidos os

brackets, foram então utilizados os dois métodos de remoção de compósito: a) pedras de Arkansas; b) brocas multilaminadas de tungsténio, ambas utilizadas em contra-ângulo (baixa rotação). Uma vez removido o compósito, foram analisadas e quantificadas as possíveis lesões advindas do procedimento. A área de compósito remanescente foi calculada em todos os dentes. A analise estatistica foi realizada utilizando o SPSSR Statistics vs.18.0, considerando um nivel de significancia de 0,05 para teste ANOVA. O teste de Tukey foi utilizado para comparações multiplas e Qui-quadrado para analise entre variaveis categoricas.

Resultados: Após a remoção do compósito com cada um dos métodos verificou-se que, relativamente ao índice adesivo remanescente (IAR), nao existiam diferenc

̧a estatisticamente significativa (p=0,283) entre metodos de remocao. Entretanto, diferenças em relaçao ao índice de rugosidade de superfície (IRS) foram estatisticamente significativas (p<0,001) com resultados a favor do metodo utilizando pedras de Arkansas.

Conclusão: Menor dano ao esmalte foi promovido pela remoçao de adesivo ortodontico com uso da pedra de Arkansas. Entretanto, polimento adicional diminui a rugosidade da superfície sem danos adicionais ao esmalte

Palavras-chave: Brackets, Lesao do esmalte, Adesivos ortodonticos

 

Introduction

The process of bonding and detachment of brackets followed by a finishing procedure after orthodontic treatment can cause iatrogenic damage of enamel surfaces. Thus, the damage on the enamel begins at the etching by orthotofosforic acid and then on the application of acidic primer to establish the bonding of the composite adhesive and bracket. After or during the orthodontic treatment, the detachment of the bracket/adhesive assembly results in cracks in the outer enamel surface. Then, the remnant composite adhesive is mechanically removed by using rotatory burs leading to a removal of enamel layers and then increasing the roughness of the enamel.1 - 3 That contribute for a opaque feature of the teeth as well as for acumulation of oral biofilm, leading to gingival irritation and an increase of stains on the enamel surface.4, 5 In the case of composite adhesive remain on enamel surface, the tooth surfaces reveal a high tendency to staining and accumulation of oral biofilms.6

The bond strength at the bracket‑adhesive‑tooth interface must withstand forces during oral movements although that strength magnitude should allow the removal of the brackets avoiding fractures in the enamel. The bond strength of the bracket‑enamel‑tooth interface should not exceed 14 MPa 7 and therefore previous studies report a proper range of bond strength from 6 up to 10 MPa.8, 9

The seek for an efficient and safe method for the removal of composite adhesive after debonding the brackets resulted  in the introduction of a wide variety of instruments and procedures. Several shapes of low or high speed burs such as tungsten carbide, Arkansas’ stones, Sof‑Lex R discs, and special finishing systems composed of zirconia or pumice slurries are used to remove composite adhesive after bracket detachment.5 , 10, 11 Technological improvement of burs has been performed, each time less aggressive to the enamel. The use of multi‑step procedures involving fine tungsten carbide burs and ultra‑fine grinding discs coated with alumina are the first choice to be considered on the removal of composite adhesives. However, the multi‑step procedures seem to be more time‑consuming and can result in a variation of enamel roughness.10,12 Polishing systems, including rubber cups embedded with diamond particles and silicon carbide brushes are used to enhance the enamel roughness resulting in a smooth appearance.13, 14 Those procedures involving burs or rubber cups produce different degrees of polishing and can promote abrasion followed by a significant loss of enamel.8

However, the clinical evaluation of the damage of the enamel is usually performed only by visual inspection or by rubbing hand scalers against the enamel surface where the bracket was bonded. A few studies have been published on other more effective methods of inspection that reveal clinical applicability.15

The main aim of this study was to compare the effectiveness of two different methods to remove orthodontic composite adhesives from enamel concerning the surface damage and remnant composite adhesive on the surfaces.

Materials and methods

Ninety two stainless steel brackets (MiniormeshTW Loant, OrmcoTM, Glendora) were randomly bonded to the buccal and lingual surfaces of twenty three human molars using a composite‑based adhesive system, as seen in Figure 1A‑D.

Previously, human molars were stored in buffer solution at room temperature and then ultrasonically cleaned in distilled water before the bonding of the brackets.

 

 

 

Following composite manufacturer’s recommendations, enamel surfaces were etched using a 37% phosphoric acid solution for 30 seconds. Surfaces were washed with distilled water for 5 min and then dried with oil‑free air at room temperature.

After etching procedure, enamel surfaces was conditioned with a primer adhesive (Ortho SoloTM, Ormco Corporation) by rubbing with a microbrush for 10 seconds. A composite adhesive system (GrenglooTM, OrmcoTM, Glendora) was used for the bonding of the brackets onto the conditioned enamel surfaces. Brackets including composite adhesive were positioned on the surfaces. The GrenglooTM composite adhesive contains a temperature‑sensitive dye, which lightens when it reaches the body temperature and returns to a green color (Figures 1E-F) when the temperature is below 37oC. The green color facilitates the detection of the adhesive, which remains around the bracket during the process of bonding.

After removal of the remaining adhesive, bracket‑composite adhesive was exposed to light‑curing using a Coltolux 75 (Coltene/Whaledent Altstatten, Switzerland) at 1000 mW/cm2 for 20 s.

After 15 days, the brackets were detached on mesial

‑distal shear loading by using the universal Weingart orthodontic plier (EQ‑Line DentaurumTM, Germany). After detachment of brackets, the adhesive

‑tooth assemblies were divided into two groups: (A) composite adhesive for removal by (A) Arkansa’s stone rotatory tip or (B) multi‑blades tungsten carbide burs.

Photographs were obtained for the remaining composite adhesive on the enamel surfaces at x40 magnification using magnifying lenses (LeicaTM Wild, Leica) coupled to a photographic camera (LeicaTM DFC295, Leica) (Figure 1E). The area of remaining composite adhesive was calculated for each surface via Leica Application Suite Software (version 3.5.0) (Figure 1F).

Then, the composite adhesive was removed by using Arkansas’stone tip (EdentaTM, Switzerland) or multi‑blade tungsten burs (OrmodentTM, Canada) at low rotatory speed for 45 s. Four rotary Arkansa’s stone tips or multi

‑blade burs were used in order to maintain a standard precision cut performance. After composite adhesive removal, photographs of the enamel surfaces were also obtained at x40 magnification for analyses considering the (ARI) adhesive remnant or (SRI) surface roughness index.16 The analysis and measurement of the ARI and SRI were performed by a researcher, blinded and well‑trained on image analysis, by using Leica Application Suite 3.5.0 Software.

ARI and SRI revealed the degree of adhesion considering a classification scale, as seen in Table 1.

 

 

 

 

Data were statistically analyzed by one‑way ANOVA at a significance level of 5% (p<0.05) using SPSS vs. 18.0 software (Chicago, USA). Tukey’s test was used for multiple comparisons and therefore Kolmogorov‑Smirnov tests were applied when required. Chi‑square tests were used to analyze the association between categorical variables.

The remnant composite adhered to the tooth as well as the teeth surfaces were also analyzed by field emission guns electron scanning microscopy (FEGSEM) coupled to energy dispersive spectroscopy (EDS) (FEI Nova 200, USA). FEGSEM images were obtained by (SE) secondary or (BSE) backscattered electrons mode at 10‑15 kV. For FEGSEM‑EDS analyses, enamel surfaces were previously sputter‑coated with Ag‑

Results

The composite adhesive area remained on enamel surfaces, is shown in Table 2 and Figure 1F.

 

 

 

 

The remnant composite adhesive removed by Arkansas‘ stone method showed a mean area of 24.20 ± 4.131 μm2 while the composite adhesive removed with tungsten carbide burs showed a less mean area at 23.52 ± 5.177 μm2. The mean area analyzed on both groups were not a statistically significant different (p = 0.488) and therefore that did not effect the ARI or SRI analyses (Table 2).

FEG‑SEM images of the enamel surfaces before bonding and after bracket detachment are shown in Figure 2.

 

 

 

Enamel surfaces after etching procedure revealed a rough feature to increase the mechanical interlocking of the orthodontic composite adhesive system as seen in Figure 2A-B. The standard morphologic aspect of the enamel surface after etching is noticed by FEGSEM. After bracket detachment, a thick composite adhesive layer remained on the enamel surface (Figure 2C-D) that was removed by the finishing technique.

FEGSEM obtained by BSE mode showed the fillers in the composite adhesive microstructure. Also, a radial thin layer of primer adhesive was noted around the composite adhesive thick layer (Figure 2D).

Results considering (ARI) adhesive remnant and (SRI) surface roughness index analyses are shown in Table 3. Images of enamel surfaces are shown in Figure 3.

 

 

 

 

 

 

 

 

Regarding ARI analysis, one case revealed values between 10 and 90% composite adhesive adhered to enamel after using the removal methods. A percentage less than 10% remaining composite adhered to enamel was found for 73 samples. Enamel surfaces free of composite adhesive were identified on 17 samples (Table 3 and Figure 3D). On Arkansas’ method group, less than 10% composite adhesive remained on enamel (Figure 3B) was detected for 35 samples while no composite adhesive was noticed on 11 samples. On tungsten bur method, 90% remaining composite adhesive adhered to enamel was detected for 1 sample (Figure 3A). Composite adhesive adhered to enamel recorded from 10 to 90% (Figure 3C) was noticed for 4 samples while less than 10% composite adhesive remained on enamel was detected for 36 samples (Table 3 and Figure 3C). No composite adhesive was only noticed on 7 samples, as shown in Figure 3D.

Regarding the surface roughness index (SRI), all 46 samples treated by Arkansas’ stone tips revealed fine and shallow scars.

Forty samples submitted to tungsten carbide bur method revealed rough surfaces with deep grooves (Figure 4C) while 3 samples showed extreme deep grooves (Figure 4D). Only 3 samples treated by tungsten carbide burs revealed fine and shallow grooves (p <0.001) as seen in Figure 4B.

 

 

 

Discussion

In this study, the photographs of orthodontic adhesive remained onto enamel surfaces obtained at x40 magnification were used to examine statistical differences concerning the damage on the enamel surfaces after using two different rotary tips to remove remaining adhesive. The finishing procedure period and the evaluation area were controlled in order to compare the effectiveness of the two methods regarding the removal of remaining composite adhesive avoiding damage on enamel. The enamel surface was also analyzed immediately before bonding and after the bracket detachment to determine that the enamel damage would be caused only by the use of the rotatory finishing tips.

After bracket detachment, only one case of enamel damaged was found in the present study. In literature, a few studies reported the enamel damage after the detachment of brackets. The shear forces induced by the use of orthodontic pliers can result in cracks in the outer enamel layer, which was etched prior to bracket bonding. Cracks can propagate leading to fracture of enamel structure.17

Regarding the adhesive remnant index used in this study, we can notice that there were no statistically significant differences between the two methods of composite adhesive removal. However, statistically significant differences were detected between the two methods considering the enamel surfaces were smoother possessing fine and shallow scars after the removal procedure using Arkansas’ stone tips when compared to that after the use of tungsten carbide burs. The tungsten carbide multi‑blade bur method induced a heterogeneous morphologic aspect of the enamel surfaces showing rougher surfaces with deeper scars. During removal of the composite adhesive by using both methods in this study, the excessive loss of enamel was prevented considering a removal period of 45 s. However, photographs obtained on enamel surfaces after adhesive removal revealed unavoidable abrasion scars due to the use of the abrasive rotatory tips or burs.

The tungsten carbide burs are available in several sizes, shapes, and different particle sizes. Tungsten carbide rotatory burs having 12 and 30 blades are the most commonly used to remove composite adhesive from enamel.5 The multi‑blade tungsten carbide rotatory bur can rapidly remove remaining composite adhesive adhered to enamel although that can destroy the outer enamel layer and increase the roughness.4 5, ,18 The hardness, shape and speed of the rotatory blades of the tungsten carbide burs play a significant role on the damage of the enamel surfaces.17 Tungsten carbide rotatory burs, at low speed, can result in a pattern of finer scars followed by less loosening of enamel, when compared to carbide drills tungsten at high speed.19, 20 The difference in cutting effectiveness of rotary abrasive tips can be determined by various parameters, such as: tool rotation speed, pressure on the handheld device during removal of the composite, the type and shape of the instrument and the flow rate through the tip to the cutting adhesive

‑tooth interface.3 Those factors were controlled in this study since removal was performed by a well

‑trained and blinded operator on the equipment and method of analysis.

The development of new methods and tools resulted in the technologic improvement of the abrasive rotatory tips, discs and burs. For instance, there are tips composed of stainless steel or silicon coated or else embedded with diamond particles at different size and shapes.11 Also, physic methods involving ultrasonic vibration or carbon dioxide and Nd:YAG laser have been used to avoid damage of the enamel.5,21

Conclusions

Within limitations of an in vitro study on the effectiveness of remaining composite adhesive removal using two different methods after bracket detachment, the main outcome on the present work can be drawn:

– comparing the effectiveness of the two methods, there were no statistically significant differences on the adhesive remnant index after the removal of composite adhesive adhered to enamel. However, statistically significant differences were detected between the both methods considering the roughness index and degree of loosening of enamel;

– Arkansas’ rotatory stone tip method at low speed was effective to remove the composite adhesive avoiding a high destruction of the outer enamel layer. Enamel surfaces revealed a homogeneous morphological aspect possessing finer scars and lower roughness after removal of composite adhesive by Arkansa’s when compared with the tungsten multi

‑blade carbide rotatory burs.

 

References

1. Andrews J, Hagan JL, Armbruster PC, Ballard RW. Comparison of traditional orthodontic polishing systems with novel non-orthodontic methods for residual adhesive removal. Aust Orthod J. 2016;32:41-7.

2. Sundfeld RH, Rahal V, Croll TP, Aalexandre RS, Briso ALF. Enamel microabrasion followed by dental bleaching for patients after Orthodontic treatment – Case reports. J Esthet Restor Dent. 2007;19:71-8.

3. Eliades T, Gioka C, Eliades G, Makou M. Enamel surface roughness debonding using two resin grinding methods. Eur J Orthod. 2004;26:333-8.

4. Dostalova T, Jelinkova H, Remes M, Šulc J, Němec M. The Use of the Er:YAG Laser for Bracket Debonding and Its Effect on Enamel Damage. Photomed Laser Surg. 2016;34:394-9.

5. Ulusoy C. Comparison of finishing and polishing systems for residual resin removal after debonding. J Appl Oral Sci. 1999;17:209-15.

6. Kim SS, Park WK, Son WS, Ahn HS, Ro JH, Kim YD. Enamel surface evaluation after removal of orthodontic composite remnants by intraoral sandblasting: A 3-dimensional surface profilometry study. Am J Orthod Dentofacial Orthop. 2007;132:71-6.

7. Pickett KL, Sadowsky PL, Jacobson A, Lacefield W. Orthodontic in vivo bond strength: comparison with in vitro results. Angle Orthod. 2001;71:141-8.

8. Eminkahyagil N, Arman A, Çetinsahin A, Karabulut E. Effect of resin- removal methods on enamel and shear bond strenght of rebonded brackets. Angle Orthod. 2006;76:314-21.

9. Pithon MM, Oliveira MV, Ruellas AC. Remoc

̧ão de braquetes cera

̂micos com alicate de How associado á broca diamantada – avaliac

̧ão da topografia do esmalte. Revista Dental Press Ortodontia e Ortopedia Facial 2008;13:101-6.

10. Vidor MM, Felix RP, Marchioro EM, Hahn L. Enamel surfasse evaluation after bracket debonding and different resin removal methods. Dental Press J Orthod. 2015;20:61-7.

11. Radlanski RJ. A new carbide finishing bur for bracket debonding. J Orofac Orthop. 2001;62:296-304.

12. Janiszewska-Olszowska J, Szatkiewicz T, Tomkowski R, Tandecka K, Grocholewicz K. Effect of orthodontic debonding and adhesive removal on the enamel – current knowledge and future perspectives – a systematic review. Med Sci Monit. 2014;20:1991-2001.

13. Ryf S, Flury S, Palaniappan S, Lussi A, Van Meerbeek B, Zimmerli B. Enamel loss and adhesive remnants following bracket removal and various clean-up procedures in vitro. Eur J Orthod. 2012;34:25-32.

14. Costa J, Ferracane J, Paravina RD, Mazur RF, Roeder L. The effect of different polishing systems on surface roughness and gloss of various resin composites. J Esthet Restor Dent. 2007;19:214-24.

15. Fonseca DM, Pinheiro FH, Medeiros SF. Sugestão de um protocolo simples e eficiente para a remoc

̧ão de braquetes ortodônticos. Revista de Estética Dental Press 2004;1:112-9.

16. Artun J, Bergland S. Clinical trials with crystal growth conditioning as an alternative to acid-etch enamel pre-treatment. Am J Orthod. 1984;85:333-40.

17. Rouleau BD, Grayson WM, Cooley RO. Enamel surface evaluations after clinical treatment and removal of orthodontic brackets. Am J Orthod. 1982;81:423-6.

18. Zarrinnia K, Eid NM, Kehoe MJ. The effect of different debonding techniques on the enamel surface: an in vitro qualitative study. Am J Orthod Dentofacial Orthop. 1995;108:284-93.

19. Van Waes H, Matter T, Krejci I. Three-dimensional measurement of enamel loss caused by bonding and debonding of orthodontic brackets. Am J Orthod Dentofacial Orthop. 1997;112:666-9.

20. Zachrisson BU, Artun J. Enamel surface appearance after various debonding techniques. Am J Orthod. 1979;75:121-37.

21. Ghazanfari R, Nokhbatolfoghahaei H, Alikhasi M. Laser-Aided Ceramic Bracket Debonding: A Comprehensive Review. J Lasers Med Sci. 2016;7:2-11.

 

*Corresponding author:

Monica Morado Pinho

E-mail address: monicap@ufp.edu.pt

 

Ethical disclosures

Protection of human and animal subjects. The authors declare that no experiments were performed on humans or animals for this study.

Confidentiality of data. The authors declare that no patient data appear in this article.

Right to privacy and informed consent. The authors declare that no patient data appear in this article.

 

Conflicts of interest

The authors have no conflicts of interest to declare.

 

Acknowledgements

This work has been supported by FCT (Fundacao para a Ciencia e Tecnologia – Portugal) in the scope of the project UID/EEA/04436/2013 NORTE-01-0145-FEDER-000018 - HAMaBICo.

 

Article history:

Received 25 October 2016

Accepted 18 December 2016

Available online 30 March 2017